Error 1User Serviceable |
Water Inlet Issue |
- Water supply valve closed
- Kinked or damaged inlet hose
- Clogged water inlet filter
- Faulty inlet valve solenoid
|
- Verify water supply valve is fully open
- Inspect and straighten any kinked hoses
- Clean the inlet filter (located at hose connection)
- Test water pressure (should be 20-120 PSI)
- If issue persists, inlet valve may need replacement
|
Error 2User Serviceable |
Drainage Problem |
- Clogged drain hose
- Blocked garbage disposal connection
- Faulty drain pump
- Blocked drain filter
|
- Remove and clean the drain filter
- Check drain hose for kinks or blockages
- Run garbage disposal to clear connection
- Verify drain hose height (max 32 inches)
- Test drain pump operation
|
Error 3Service Required |
Heating System Error |
- Failed heating element
- Defective temperature sensor
- Control board malfunction
- Wiring issues
|
- Immediately unplug the dishwasher
- Do not attempt to run any cycles
- Contact authorized Viking service technician
- Heating element will require professional testing
|
Error 4User Serviceable |
Door Latch Error |
- Door not fully closed
- Damaged latch mechanism
- Faulty door sensor
- Misaligned door
|
- Check for items blocking door closure
- Clean latch mechanism of debris
- Inspect door hinges for damage
- Test door sensor operation
- Adjust door alignment if necessary
|
Error 5Service Required |
Power Supply Error |
- Loose power connection
- Damaged power cord
- Internal wiring fault
- Control board power issue
|
- Check power cord connection
- Verify circuit breaker status
- Inspect for visible cord damage
- Contact qualified electrician
|
Error 6Service Required |
Control Panel Error |
- Failed control board
- Touchpad malfunction
- Display panel failure
- Software error
|
- Perform hard reset (unplug for 5 minutes)
- Check for water damage to panel
- Document any visible display issues
- Schedule professional diagnosis
|
Error 7Service Required |
Temperature Sensor Error |
- Failed temperature sensor
- Wiring harness damage
- Control board communication error
- Sensor calibration issue
|
- Do not use heated dry function
- Record temperature-related symptoms
- Contact authorized service technician
- Sensor replacement likely needed
|
Error 8User Serviceable |
Water Level Error |
- Faulty float switch
- Clogged water inlet
- Water pressure too low
- Inlet valve problem
|
- Check home water pressure
- Clean inlet screens and filters
- Verify float switch movement
- Test inlet valve operation
|
Error 9Service Required |
Heating Element Error |
- Burned out heating element
- Thermostat failure
- Relay malfunction
- Wiring short circuit
|
- Stop using heated dry cycle
- Check for error codes
- Schedule professional repair
- Element requires multimeter testing
|
Error 10Service Required |
System Communication Error |
- Main control board failure
- Interface board problem
- Wiring harness damage
- Software corruption
|
- Perform complete power reset
- Document all error messages
- Contact Viking technical support
- Professional diagnosis required
|